ECO G W-Multi 2 Way for Heat Pump Applications
The product range image
Product description

The new and improved M Series 2 Way not only offers improved performance but also increased flexibility. Now available as multi-systems, many combinations are possible, from 13HP to 50HP, allowing for more power and enabling accurate matching of a system building load. Additional new features include part load engine management and compressor run hour equalisation.

Features and benefits

  • Reduced gas consumption by Miller-cycle engine
  • Reduced electrical power consumption by using DC motors
  • New lightweight design by use of aluminium engine block reduces weight by 110kg
  • Part load efficiencies increased
  • Connectability increased - now up to 48 indoor units
  • Multi-systems with combinations from 13HP up to 50HP
  • 200m maximum allowable piping length (L1)
  • Diversity ratio 50-200% (single models only; excluding ECO G Power)
  • Extended pipe runs (total 780m)
  • Equivalent sound levels to electric VRF systems
  • Quiet mode offers a further 2dB(A) reduction
  • Chiller option
    - 9HP (25kW cooling - 30kW heating)
    - 18HP (50kW cooling - 60kW heating)
  • 10,000 run hours between engine service intervals
  • (equivalent to one maintenance every 3.2 years*)
  • Full heating capacity down to -20°C
  • No defrost cycle
    * Assuming 3120 running hrs per year - 12 hrs x 5 days x 52 weeks
New M Series 2-Way W-Multi

Previous Model -                                               

K-Series 3 x 45kW units (135kW)              New M Series 2 Way W Multi 2 x 71KW (142kW)

 

 

Advantages of ECO G W-Multi

Depending on buildings requirements load can be quickly and efficiently increased or decreased

 

 

 

Rotate function averages out running hours

 

  • Running hours reduced by 40% by load sharing
  • Back-up mode means no down time during maintenance

 

Hot water supply function (during cooling operation only)

SGP-E120K1GU2W - SGP-E150K1GU2W - SGP-E190K1GU2W - SGP-E240K1GU2W

 

The engine waste heat, which is normally exhausted into the atmosphere, is recovered via the heat exchanger and effectively used as hot water, so the GHP chiller acts as a sub system that alleviates the load on the client's main hot water system and therefore offers ‘free’ hot water.

Technical specifications
Model Number SGP-EW120M2G2W SGP-EW150M2G2W SGP-EW190M2G2W SGP-EW240M2G2W
Unit 1 SGP-EW120M2G2W SGP-EW150M2G2W SGP-EW190M2G2W SGP-EW240M2G2W
Unit 2 - - - -
HP 13 16 20 25
Capacity Cooling - kW 35.5 45.0 56.0 71.0
Capacity Heating STD - kW 40.0 50.0 63.0 80.0
Capacity Heating Low temp*1 - kW 42.5 53.0 67.0 75.0
Capacity Hot water (cooling mode) - kW 12.0 16.0 20.0 25.0
Electricity Cooling - kW 0.85 1.35 1.35 1.35
Electricity Heating - kW 1.01 1.01 1.01 1.54
Gas consumption - Cooling (kW) 24.5 31.6 38.3 60.9
Gas consumption - Heating STD 28.1 36.1 43.0 58.0
Gas consumption - Heating LOW (kW) 36.8 47.3 56.4 64.9
C O P - Cooling 1.40 1.37 1.41 1.14
C O P - Heating 1.37 1.35 1.43 1.34
C O P - AVE 1.39 1.36 1.42 1.24
Max COP (inc hot water) - Cooling 1.87 1.85 1.92 1.54
Size Height - mm 2,248 2,248 2,248 2,248
Size Width - mm 1,800 1,800 1,800 1,800
Size Depth - mm 1,000 (+60) 1,000 (+60) 1,000 (+60) 1,000 (+60)
Weight kg 790 790 820 850
Starter amperes (A) 30 30 30 30
Pipe Gas ø25.4 ø28.58 ø28.58 ø28.58
Pipe Liquid ø12.7 ø12.70 ø15.88 ø15.88
Pipe Balance ø9.52 ø9.52 ø9.52 ø9.52
Pipe Fuel gas R3/4 (bolt thread) R3/4 (bolt thread) R3/4 (bolt thread) R3/4 (bolt thread)
Pipe Exhaust drain ø25 rubber hose ø25 rubber hose ø25 rubber hose ø25 rubber hose
Operation sound - dB(A) 57 57 58 62
Indoor/outdoor capacity ratio 50-200 % 50-200 % 50-200 % 50-200 %
Number of indoor connections 32 36 36 36
*1 Low temp condition: outdoor temperature 2degC - - - -
Model Number SGP-EW120M2G2W/ SGP-EW120M2G2W SGP-EW120M2G2W/ SGP-EW150M2G2W SGP-EW150M2G2W/ SGP-EW150M2G2W SGP-EW120M2G2W/ SGP-EW190M2G2W
Unit 1 SGP-EW120M2G2W SGP-EW120M2G2W SGP-EW150M2G2W SGP-EW120M2G2W
Unit 2 SGP-EW120M2G2W SGP-EW150M2G2W SGP-EW150M2G2W SGP-EW190M2G2W
HP 26 29 32 33*
Capacity Cooling - kW 71.0 80.5 90.0 91.5
Capacity Heating STD - kW 80.0 90.0 100.0 103.0
Capacity Heating Low temp*1 - kW 85.0 95.5 106.0 109.5
Capacity Hot water (cooling mode) - kW 24.0 28.0 32.0 32.0
Electricity Cooling - kW 1.70 2.20 2.70 2.20
Electricity Heating - kW 2.02 2.02 2.02 2.02
Gas consumption - Cooling (kW) 49.0 56.1 63.2 62.8
Gas consumption - Heating STD 56.2 64.2 72.2 71.1
Gas consumption - Heating LOW (kW) 73.6 84.1 94.6 93.2
C O P - Cooling 1.40 1.38 1.37 1.41
C O P - Heating 1.37 1.36 1.35 1.41
C O P - AVE 1.39 1.37 1.36 1.41
Max COP (inc hot water) - Cooling 1.87 1.86 1.85 1.90
Size Height - mm 2,248 2,248 2,248 2,248
Size Width - mm 1,800 + 100 (min distance) + 1,800 (in a straight installation) 1,800 + 100 (min distance) + 1,800 (in a straight installation) 1,800 + 100 (min distance) + 1,800 (in a straight installation) 1,800 + 100 (min distance) + 1,800 (in a straight installation)
Size Depth - mm 1,000 (+60) 1,000 (+60) 1,000 (+60) 1,000 (+60)
Weight kg 1,580 1,580 1,580 1,610
Starter amperes (A) 30 30 30 30
Pipe Gas ø31.75 ø31.75 ø31.75 ø31.75
Pipe Liquid ø15.88 ø19.05 ø19.05 ø19.05
Pipe Balance ø9.52 ø9.52 ø9.52 ø9.52
Pipe Fuel gas R3/4 (bolt thread) R3/4 (bolt thread) R3/4 (bolt thread) R3/4 (bolt thread)
Pipe Exhaust drain ø25 rubber hose ø25 rubber hose ø25 rubber hose ø25 rubber hose
Operation sound - dB(A) 60 60 60 61
Indoor/outdoor capacity ratio 50-130 % 50-130 % 50-130 % 50-130 %
Number of indoor connections 48 48 48 48
*1 Low temp condition: outdoor temperature 2degC - - - -
Model Number SGP-EW150M2G2W/ SGP-EW190M2G2W SGP-EW190M2G2W/ SGP-EW190M2G2W SGP-EW190M2G2W/ SGP-EW240M2G2W SGP-EW240M2G2W/ SGP-EW240M2G2W
Unit 1 SGP-EW150M2G2W SGP-EW190M2G2W SGP-EW190M2G2W SGP-EW240M2G2W
Unit 2 SGP-EW190M2G2W SGP-EW190M2G2W SGP-EW240M2G2W SGP-EW240M2G2W
HP 36* 40* 45* 50
Capacity Cooling - kW 101.0 112.0 127.0 142.0
Capacity Heating STD - kW 113.0 126.0 143.0 160.0
Capacity Heating Low temp*1 - kW 120.0 134.0 142.0 150.0
Capacity Hot water (cooling mode) - kW 36.0 40.0 45.0 50.0
Electricity Cooling - kW 2.70 2.70 2.70 2.70
Electricity Heating - kW 2.02 2.02 2.55 3.08
Gas consumption - Cooling (kW) 69.9 76.6 99.2 121.8
Gas consumption - Heating STD 79.1 86.0 101.0 116.0
Gas consumption - Heating LOW (kW) 103.7 112.8 121.3 129.8
C O P - Cooling 1.39 1.41 1.25 1.14
C O P - Heating 1.39 1.43 1.38 1.34
C O P - AVE 1.39 1.42 1.31 1.24
Max COP (inc hot water) - Cooling 1.89 1.92 1.69 1.54
Size Height - mm 2,248 2,248 2,248 2,248
Size Width - mm 1,800 + 100 (min distance) + 1,800 (in a straight installation) 1,800 + 100 (min distance) + 1,800 (in a straight installation) 1,800 + 100 (min distance) + 1,800 (in a straight installation) 1,800 + 100 (min distance) + 1,800 (in a straight installation)
Size Depth - mm 1,000 (+60) 1,000 (+60) 1,000 (+60) 1,000 (+60)
Weight kg 1,610 1,640 1,670 1,700
Starter amperes (A) 30 30 30 30
Pipe Gas ø31.75 ø38.10 ø38.10 ø38.10
Pipe Liquid ø19.05 ø19.05 ø19.05 ø19.05
Pipe Balance ø9.52 ø9.52 ø9.52 ø9.52
Pipe Fuel gas R3/4 (bolt thread) R3/4 (bolt thread) R3/4 (bolt thread) R3/4 (bolt thread)
Pipe Exhaust drain ø25 rubber hose ø25 rubber hose ø25 rubber hose ø25 rubber hose
Operation sound - dB(A) 61 61 63 65
Indoor/outdoor capacity ratio 50-130 % 50-130 % 50-130 % 50-130 %
Number of indoor connections 48 48 48 48
*1 Low temp condition: outdoor temperature 2degC - - - -
Rating Conditions

The cooling and heating capacities are based on the following conditions:

Cooling: Indoor temperature 27°C DB/19°C WB, Outdoor temperature 35°C DB/24° C WB.
Heating: Indoor temperature 20°C DB, Outdoor Temperature 7°C DB 6°C WB.

All specifications are subject to change without notice.

SANYO reserves the right to make any variations to the equipment described or to withdraw or replace products
without prior notification.

All descriptions, illustrations, drawings and specifications on this site are given in good faith, but are intended to
present only general particulars.