ECO G Power
Product description
NEW 2 way gas driven VRF with electrical power generator SANYO’s ECO G Power is a revolution in air conditioning design. Fitted with a permanent magnet, non-bearing type generator, it is the first VRF system that can supply heating, cooling, hot water and now also a supply of electrical power.
Each ECO G Power unit has a 4.0kW generator, which provides enough power for 40 indoor units or the equivalent of 8 computers.
Features and benefits
- Innovative technology that reduces CO2 emissions by more than 30%
- 2 way air conditioning system providing cooling or heating
- Can provide both electricity and hot water in heating and cooling mode
- Up to 4kW electricity generated
- Provides power for indoor units
- Very efficient generator
- Electricity is output to line linkage converter
- Hot water provided when cooling and when heating above 7°C*
- 22kW hot water generation capacity
- 20HP model provides 56kW cooling or 63kW heating
- Can connect to up to 24 indoor units
- 200m maximum allowable piping length (L1)
- IU/OU capacity ratio 50 - 130% * referring to outside temperature

Generate electricity during heating or cooling operation
Generate electricity and air conditioning (heating or cooling) at the same time by using remaining engine power. ECO G Power can generate from 2.3 to 3.95kW electricity at a generation effi ciency of more than 40%.
Production of electricity
Generates from 2kW to 4kW depending on air conditioning load
Documents
-
Gas Driven VRF (GHP) 2009.pdf (1.8Mb)
-
_UK NEW PRODUCT RANGE 2009_10.pdf (11.3Mb)
-
SANYO_GHP_MSeries_2008v3.pdf (10.0Mb)
Technical specifications
| Model Number | SGP-EGW190M2G2W | SGP-EW120M2G2W/ SGP-EGW190M2G2W | SGP-EW150M2G2W/ SGP-EGW190M2G2W | SGP-EGW190M2G2W/ SGP-EGW190M2G2W |
| Unit 1 | SGP-EGW190M2G2W | SGP-EW120M2G2W | SGP-EW150M2G2W | SGP-EGW190M2G2W |
| Unit 2 | - | SGP-EGW190M2G2W | SGP-EGW190M2G2W | SGP-EGW190M2G2W |
| HP | 20 | 33 | 36 | 40 |
| Capacity Cooling - kW | 56.0 | 91.5 | 101.0 | 112.0 |
| Capacity Heating STD - kW | 63.0 | 103.0 | 113.0 | 126.0 |
| Capacity Heating Low temp*1 - kW | 67.0 | 109.5 | 120.0 | 134.0 |
| Capacity Hot water (cooling mode) - kW | 22.0 | 34.0 | 37.5 | 44.0 |
| Power generater capacity at rating - kW | DC 2.5 (Max 4.3) | DC 2.5 (Max 4.3) | DC 2.5 (Max 4.3) | DC 5.0 (Max 8.6) |
| Electricity Cooling - kW | 1.35 | 2.20 | 2.70 | 2.70 |
| Electricity Heating - kW | 1.01 | 2.02 | 2.02 | 2.02 |
| Gas consumption Cooling - kW | 44.0 (38.3)* | 68.5 | 75.6 | 88.0 |
| Gas consumption Heating STD - kW | 48.7 (43.0)* | 76.8 | 84.8 | 97.4 |
| Gas consumption Heating LOW - kW | 62.1 (56.4)* | 98.9 | 109.4 | 124.2 |
| C O P Air conditioning only Cooling | 1.33 (1.41)* | 1.29 | 1.29 | 1.23 |
| C O P Air conditioning only Heating | 1.34 (1.43)* | 1.31 | 1.30 | 1.27 |
| C O P Air conditioning only AVE | 1.34 (1.42)* | 1.30 | 1.30 | 1.25 |
| Max COP (Inc generater, hot water) Cooling | 1.78 | 1.81 | 1.80 | 1.78 |
| Size Height - mm | 2,248 | 2,248 | 2,248 | 2,248 |
| Size Width - mm | 1,800 | 1,800 + 100 (Min distance) + 1,800 | 1,800 + 100 (Min distance) + 1,800 | 1,800 + 100 (Min distance) + 1,800 |
| Size Depth | 1,000 (+60) | 1,000 (+60) | 1,000 (+60) | 1,000 (+60) |
| Weight - kg | 875 | 1,660 | 1,685 | 1,740 |
| Starter amperes (A) | 30 | 30 | 30 | 30 |
| Pipe Gas | ø28.58 | ø31.75 | ø31.75 | ø38.10 |
| Pipe Liquid | ø15.88 | ø19.05 | ø19.05 | ø19.05 |
| Pipe Balance | ø9.52 | ø9.52 | ø9.52 | ø9.52 |
| Pipe Fuel gas | R3/4 (bolt, thread) | R3/4 (bolt, thread) | R3/4 (bolt, thread) | R3/4 (bolt, thread) |
| Pipe Exhaust drain port - (mm) | ø25 rubber hose | ø25 rubber hose | ø25 rubber hose | ø25 rubber hose |
| Operation sound - dB(A) | 58 | 61 | 61 | 61 |
| Indoor/outdoor capacity ratio | 50-1300% | 50-130% | 50-130% | 50-130% |
| Number of connections indoor* | 32 | 48 | 48 | 48 |
| *In case of not generating working *1 Low temp condition: outdoor temperature 2degC | - | - | - | - |
| Model Number | SGP-EGW190M2G2W/ SGP-EW240M2G2W |
| Unit 1 | SGP-EGW190M2G2W |
| Unit 2 | SGP-EW240M2G2W |
| HP | 45 |
| Capacity Cooling - kW | 127.0 |
| Capacity Heating STD - kW | 143.0 |
| Capacity Heating Low temp*1 - kW | 142.0 |
| Capacity Hot water (cooling mode) - kW | 52.0 |
| Power generater capacity at rating - kW | DC 2.5 (Max 4.3) |
| Electricity Cooling - kW | 2.70 |
| Electricity Heating - kW | 2.55 |
| Gas consumption Cooling - kW | 104.9 |
| Gas consumption Heating STD - kW | 101.0 |
| Gas consumption Heating LOW - kW | 121.3 |
| C O P Air conditioning only Cooling | 1.18 |
| C O P Air conditioning only Heating | 1.38 |
| C O P Air conditioning only AVE | 1.28 |
| Max COP (Inc generater, hot water) Cooling | 1.69 |
| Size Height - mm | 2,248 |
| Size Width - mm | 1,800 + 100 (Min distance) + 1,800 |
| Size Depth | 1,000 (+60) |
| Weight - kg | 1,720 |
| Starter amperes (A) | 30 |
| Pipe Gas | ø38.10 |
| Pipe Liquid | ø19.05 |
| Pipe Balance | ø9.52 |
| Pipe Fuel gas | R3/4 (bolt, thread) |
| Pipe Exhaust drain port - (mm) | ø25 rubber hose |
| Operation sound - dB(A) | 63 |
| Indoor/outdoor capacity ratio | 50-130% |
| Number of connections indoor* | 48 |
| *In case of not generating working *1 Low temp condition: outdoor temperature 2degC | - |
The cooling and heating capacities are based on the following conditions:
Cooling: Indoor temperature 27°C DB/19°C WB, Outdoor temperature 35°C DB/24° C WB.
Heating: Indoor temperature 20°C DB, Outdoor Temperature 7°C DB 6°C WB.
All specifications are subject to change without notice.
SANYO reserves the right to make any variations to the equipment described or to withdraw or replace products
without prior notification.
All descriptions, illustrations, drawings and specifications on this site are given in good faith, but are intended to
present only general particulars.