GHP with electricity generation and hot water supply
The product range image
Product description

NEW 2 way gas driven VRF with electrical power generator SANYO’s ECO G Power is a revolution in air conditioning design. Fitted with a permanent magnet, non-bearing type generator, it is the first VRF system that can supply heating, cooling, hot water and now also a supply of electrical power.

Each ECO G Power unit has a 4.0kW generator, which provides enough power for 40 indoor units or the equivalent of 8 computers.

Features and benefits

  • Innovative technology that reduces CO2 emissions by more than 30%
  • 2 way air conditioning system providing cooling or heating
  • Can provide both electricity and hot water in heating and cooling mode
  • Up to 4kW electricity generated
  • Provides power for indoor units
  • Very efficient generator
  • Electricity is output to line linkage converter
  • Hot water provided when cooling and when heating above 7°C*
  • 22kW hot water generation capacity
  • 20HP model provides 56kW cooling or 63kW heating
  • Can connect to up to 24 indoor units
  • 200m maximum allowable piping length (L1)
  • IU/OU capacity ratio 50 - 130%
  • * referring to outside temperature

 

Generate electricity during heating or cooling operation

Generate electricity and air conditioning (heating or cooling) at the same time by using remaining engine power. ECO G Power can generate from 2.3 to 3.95kW electricity at a generation effi ciency of more than 40%.

Production of electricity

Generates from 2kW to 4kW depending on air conditioning load

 

 

Technical specifications
Model Number SGP-EGW190M2G2W SGP-EW120M2G2W/ SGP-EGW190M2G2W SGP-EW150M2G2W/ SGP-EGW190M2G2W SGP-EGW190M2G2W/ SGP-EGW190M2G2W
Unit 1 SGP-EGW190M2G2W SGP-EW120M2G2W SGP-EW150M2G2W SGP-EGW190M2G2W
Unit 2 - SGP-EGW190M2G2W SGP-EGW190M2G2W SGP-EGW190M2G2W
HP 20 33 36 40
Capacity Cooling - kW 56.0 91.5 101.0 112.0
Capacity Heating STD - kW 63.0 103.0 113.0 126.0
Capacity Heating Low temp*1 - kW 67.0 109.5 120.0 134.0
Capacity Hot water (cooling mode) - kW 22.0 34.0 37.5 44.0
Power generater capacity at rating - kW DC 2.5 (Max 4.3) DC 2.5 (Max 4.3) DC 2.5 (Max 4.3) DC 5.0 (Max 8.6)
Electricity Cooling - kW 1.35 2.20 2.70 2.70
Electricity Heating - kW 1.01 2.02 2.02 2.02
Gas consumption Cooling - kW 44.0 (38.3)* 68.5 75.6 88.0
Gas consumption Heating STD - kW 48.7 (43.0)* 76.8 84.8 97.4
Gas consumption Heating LOW - kW 62.1 (56.4)* 98.9 109.4 124.2
C O P Air conditioning only Cooling 1.33 (1.41)* 1.29 1.29 1.23
C O P Air conditioning only Heating 1.34 (1.43)* 1.31 1.30 1.27
C O P Air conditioning only AVE 1.34 (1.42)* 1.30 1.30 1.25
Max COP (Inc generater, hot water) Cooling 1.78 1.81 1.80 1.78
Size Height - mm 2,248 2,248 2,248 2,248
Size Width - mm 1,800 1,800 + 100 (Min distance) + 1,800 1,800 + 100 (Min distance) + 1,800 1,800 + 100 (Min distance) + 1,800
Size Depth 1,000 (+60) 1,000 (+60) 1,000 (+60) 1,000 (+60)
Weight - kg 875 1,660 1,685 1,740
Starter amperes (A) 30 30 30 30
Pipe Gas ø28.58 ø31.75 ø31.75 ø38.10
Pipe Liquid ø15.88 ø19.05 ø19.05 ø19.05
Pipe Balance ø9.52 ø9.52 ø9.52 ø9.52
Pipe Fuel gas R3/4 (bolt, thread) R3/4 (bolt, thread) R3/4 (bolt, thread) R3/4 (bolt, thread)
Pipe Exhaust drain port - (mm) ø25 rubber hose ø25 rubber hose ø25 rubber hose ø25 rubber hose
Operation sound - dB(A) 58 61 61 61
Indoor/outdoor capacity ratio 50-1300% 50-130% 50-130% 50-130%
Number of connections indoor* 32 48 48 48
*In case of not generating working *1 Low temp condition: outdoor temperature 2degC - - - -
Model Number SGP-EGW190M2G2W/ SGP-EW240M2G2W
Unit 1 SGP-EGW190M2G2W
Unit 2 SGP-EW240M2G2W
HP 45
Capacity Cooling - kW 127.0
Capacity Heating STD - kW 143.0
Capacity Heating Low temp*1 - kW 142.0
Capacity Hot water (cooling mode) - kW 52.0
Power generater capacity at rating - kW DC 2.5 (Max 4.3)
Electricity Cooling - kW 2.70
Electricity Heating - kW 2.55
Gas consumption Cooling - kW 104.9
Gas consumption Heating STD - kW 101.0
Gas consumption Heating LOW - kW 121.3
C O P Air conditioning only Cooling 1.18
C O P Air conditioning only Heating 1.38
C O P Air conditioning only AVE 1.28
Max COP (Inc generater, hot water) Cooling 1.69
Size Height - mm 2,248
Size Width - mm 1,800 + 100 (Min distance) + 1,800
Size Depth 1,000 (+60)
Weight - kg 1,720
Starter amperes (A) 30
Pipe Gas ø38.10
Pipe Liquid ø19.05
Pipe Balance ø9.52
Pipe Fuel gas R3/4 (bolt, thread)
Pipe Exhaust drain port - (mm) ø25 rubber hose
Operation sound - dB(A) 63
Indoor/outdoor capacity ratio 50-130%
Number of connections indoor* 48
*In case of not generating working *1 Low temp condition: outdoor temperature 2degC -
Rating Conditions

The cooling and heating capacities are based on the following conditions:

Cooling: Indoor temperature 27°C DB/19°C WB, Outdoor temperature 35°C DB/24° C WB.
Heating: Indoor temperature 20°C DB, Outdoor Temperature 7°C DB 6°C WB.

All specifications are subject to change without notice.

SANYO reserves the right to make any variations to the equipment described or to withdraw or replace products
without prior notification.

All descriptions, illustrations, drawings and specifications on this site are given in good faith, but are intended to
present only general particulars.