ECOi 2 Way – features at a glance
The product range image
  • Features
  • Download brochure

    Electric_VRF_2009_16pg.pdf

     

    For additional downloadable brochures please find links further down the page

Product description

ECOi 2 Way is a high-performance multi system with excellent energy-saving features, designed for creating comfortable environment when either heating or cooling is required.

Features and benefits

  • Heat pump systems offer heating or cooling
  • Single footprint size for all unit capacities
  • DC inverter technology combined with R410A for excellent efficiency
  • System configuration from 8HP to 48HP
  • Diversity ratio 50-130%
  • Industry low outdoor unit sound levels: from 54.5dB(A)
  • Quiet mode offers a further 3dB(A) reduction
  • Extended pipe runs of up to 150m
  • COPs up to 4.10
  • Heating capacity to -20°C
  • Connectability of 40 indoor units from 24HP upwards
  • Units available from 8-16HP as single units
  • Nominal ESP standard on all outdoor units

Extended compressor life

The compressor running time is monitored and optimised by a microcomputer to ensure that there is no imbalance in the operation times of compressors on the same refrigerant circuit.

 

Save on piping cost

R410A with low pressure loss enables smaller pipe sizes. This means reduced piping space, improved workability at the site and reduced piping material costs. Extended operating range - better output at lower temperatures. The operating range of heating has been extended from 16C° to 30C°.

 

Increased performance

SANYO continues to raise the performance by introducing new heat exchanger designs. The new ECOi 2 way system has improved its COP by 12% - one of the highest COPs in the industry. Longer piping means greater installation area. Reducing the refrigerant volume by reducing piping size has extended the piping actual length to 150m (175m equivalent piping length).

 

Longer piping means greater installation area

Reducing the refrigerant volume by reducing piping size has extended the piping actual length to 150m (175m equivalent piping length).

 

Technical specifications
Model Number C0705DXHN8 C0905DXHN8 C1155DXHN8 C1305DXHN8
Unit 1 C0705DXHN8 C0905DXHN8 C1155DXHN8 C1305DXHN8
Unit 2 - - - -
Unit 3 - - - -
HP 8 10 12 14
Power supply 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50Hz 380/400/415V-3 phase/50Hz 380/400/415V-3 phase/50Hz
Cooling capacity - (kW) 22.40 28.00 33.50 40.00
Heating capacity - (kW) 25.00 31.50 37.50 45.00
EER Cooling 3.74 3.54 3.50 3.45
COP Heating 4.05 4.10 3.91 3.91
Electric rating - cooling - Running current (AMPs) 9.7/9.2/8.9 12.9/12.3/11.8 15.6/14.9/14.3 19.6/18.6/17.9
Electric rating - cooling - Power input (kW) 5.99 7.90 9.58 11.60
Electric rating - heating - Running current (AMPs) 10.0/9.5/9.1 12.7/12.0/11.6 15.7/14.9/14.3 19.4/18.5/17.9
Electric rating - heating - Power input (kW) 6.17 7.75 9.60 11.50
Recommended fuse sizes (motor rated) 32 32 32 40
Dimensions (H/W/D) - mm 1887×890×890 (+60) 1887×890×890 (+60) 1887×890×890 (+60) 1887×890×890 (+60)
Net weight - (kg) 245 295 295 345
Air circulation - (m3/min) 150 160 180 200
Piping connection - Gas - Inches (mm) 3/4 (19.05) 7/8 (22.22) 1 (25.40) 1 (25.40)
Piping connection - Liquid - Inches (mm) 3/8 (9.52) 3/8 (9.52) 1/2 (12.7) 1/2 (12.7)
Piping connection - Balance - Inches (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Operating sound - normal mode - dB(A) 54.5 55.0 56.0 61.0
Operating sound - quiet mode - dB(A) 51.5 52.0 53.0 58.0
Ambient temperature operating range Cooling -10°C DB +43°C DB -10°C DB +43°C DB -10°C DB + 43°C DB -10°C DB + 43°C DB
Ambient temperature operating range Heating -20°C WB +15°C WB -20°C WB +15°C WB -20°C WB + 15°C WB -20°C WB + 15°C WB
Maximum number of indoor units 13 16 19 23
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. * Please refer to tube sizing charts for pipe selections and pipe length parameters
Model Number C1405DXHN8 C0905DXHN8/ C0705DXHN8 C0905DXHN8/ C0905DXHN8 C1155DXHN8/ C0905DXHN8
Unit 1 C1405DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8
Unit 2 - 8 C0705DXHN8 10 C0905DXHN8 10 C0905DXHN8
Unit 3 - - - -
HP 16 18 20 22
Power supply 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50Hz 380/400/415V-3 phase/50Hz 380/400/415V-3 phase/50Hz
Cooling capacity - (kW) 45.00 50.40 56.00 61.50
Heating capacity - (kW) 50.00 56.50 63.00 69.00
EER Cooling 3.38 3.63 3.54 3.51
COP Heating 3.79 4.06 4.06 3.97
Electric rating - cooling - Running current (AMPs) 22.5/21.3/21.6 22.7/21.6/20.8 26.0/24.7/23.8 28.6/27.2/26.2
Electric rating - cooling - Power input (kW) 13.30 13.90 15.80 17.50
Electric rating - heating - Running current (AMPs) 22.3/21.2/20.4 22.7/21.6/20.8 25.5/24.2/23.3 28.4/27.0/26.0
Electric rating - heating - Power input (kW) 13.20 13.90 15.50 17.40
Recommended fuse sizes (motor rated) 40 32x2 32x2 32x2
Dimensions (H/W/D) - mm 1887×890×890 (+60) 1887×1880×890 (+60) 1887×1880×890 (+60) 1887×1880×890 (+60)
Net weight - (kg) 345 540 590 590
Air circulation - (m3/min) 220 160+150 160+160 180+160
Piping connection - Gas - Inches (mm) 1 1/8 (28.58) 1 1/8 (28.58) 1 1/8 (28.58) 1 1/8 (28.58)
Piping connection - Liquid - Inches (mm) 1/2 (12.7) 5/8 (15.88) 5/8 (15.88) 5/8 (15.88)
Piping connection - Balance - Inches (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Operating sound - normal mode - dB(A) 62.0 58.0 58.0 58.5
Operating sound - quiet mode - dB(A) 59.0 55.0 55.0 55.5
Ambient temperature operating range Cooling -10°C DB +43°CDB -10°C DB +43°C DB -10°C DB +43°C DB -10°C DB +43°C DB
Ambient temperature operating range Heating -20°C DB +15°CDB -20°C WB +15°C WB -20°C WB +15°C WB -20°C WB +15°C WB
Maximum number of indoor units 26 29 33 36
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. * Please refer to tube sizing charts for pipe selections and pipe length parameters
Model Number C1305DXHN8/ C0905DXHN8 C1405DXHN8/ C0905DXHN8 C1405DXHN8/ C1155DXHN8 C1405DXHN8/ C1305DXHN8
Unit 1 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8
Unit 2 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8
Unit 3 - - - -
HP 24 26 28 30
Power supply 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz
Cooling capacity - (kW) 68.00 73.00 78.50 85.00
Heating capacity - (kW) 76.50 81.50 87.50 95.00
EER Cooling 3.49 3.44 3.43 3.41
COP Heating 3.96 3.88 3.84 3.85
Electric rating - cooling - Running current (AMPs) 32.4/30.8/29.6 35.4/33.6/32.4 38.2/36.3/35.0 42.0/39.9/38.5
Electric rating - cooling - Power input (kW) 19.50 21.2 22.9 24.9
Electric rating - heating - Running current (AMPs) 32.0/30.4/29.0 35.1/33.3/32.1 39.1/36.2/34.9 41.7/39.6/38.2
Electric rating - heating - Power input (kW) 19.3 21.0 22.8 24.7
Recommended fuse sizes (motor rated) 1x40 1x32 1x40 1x32 1x40 1x32 2x40
Dimensions (H/W/D) - mm 1887×1880×890 (+60) 1887×1880×890 (+60) 1887×1880×890 (+60) 1887×1880×890 (+60)
Net weight - (kg) 640 640 640 690
Air circulation - (m3/min) 200+160 220+160 220+180 220+200
Piping connection - Gas - Inches (mm) 1 1/8 (28.58) 1 3/8 (31.75) 1 3/8 (31.75) 1 3/8 (31.75)
Piping connection - Liquid - Inches (mm) 5/8 (15.88) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05)
Piping connection - Balance - Inches (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Operating sound - normal mode - dB(A) 62.0 63.0 63.0 64.5
Operating sound - quiet mode - dB(A) 59.0 60.0 60.0 61.5
Ambient temperature operating range Cooling -10°C DB +43°CDB -10°C DB +43°CDB -10°C DB +43°CDB -10°C DB +43°CDB
Ambient temperature operating range Heating -20°C DB +15°CDB -20°C DB +15°CDB -20°C DB +15°CDB -20°C DB +15°CDB
Maximum number of indoor units 40 40 40 40
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. * Please refer to tube sizing charts for pipe selections and pipe length parameters
Model Number C1405DXHN8/ C1405DXHN8 C1305DXHN8/ C0905DXHN8/ C0905DXHN8 C1405DXHN8/ C0905DXHN8/ C0905DXHN8 C1405DXHN8/ C1155DXHN8/ C0905DXHN8
Unit 1 16 C1405DXHN8 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8
Unit 2 16 C1405DXHN8 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8
Unit 3 - 10 C0905DXHN8 10 C0905DXHN8 10 C0905DXHN8
HP 32 34 36 38
Power supply 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz
Cooling capacity - (kW) 90.00 96.00 101.00 107.00
Heating capacity - (kW) 100.00 108.00 113.00 119.00
EER Cooling 3.38 3.50 3.47 3.47
COP Heating 3.79 4.00 3.94 3.89
Electric rating - cooling - Running current (AMPs) 44.9/42.7/41.1 45.4/43.1/41.6 48.2/45.8/44.1 51.0/48.0/47.0
Electric rating - cooling - Power input (kW) 26.6 27.4 29.1 30.8
Electric rating - heating - Running current (AMPs) 44.6/42.3/40.8 44.7/42.5/41.0 47.6/45.2/43.5 51.0/48.0/46.0
Electric rating - heating - Power input (kW) 26.4 27.0 28.7 30.6
Recommended fuse sizes (motor rated) 2x40 2x32 1x40 2x32 1x40 2x32 2x40
Dimensions (H/W/D) - mm 1887×1880×890 (+60) 1887×2870×890 (+60) 1887×2870×890 (+60) 1887×2870×890 (+60)
Net weight - (kg) 690 929 929 929
Air circulation - (m3/min) 220+220 200+160+160 220+160+160 220+180+160
Piping connection - Gas - Inches (mm) 1 3/8 (31.75) 1 3/8 (31.75) 1 5/8 (38.1) 1 5/8 (38.1)
Piping connection - Liquid - Inches (mm) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05)
Piping connection - Balance - Inches (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Operating sound - normal mode - dB(A) 65.0 63.0 63.5 63.5
Operating sound - quiet mode - dB(A) 62.0 60.0 60.5 60.5
Ambient temperature operating range Cooling -10°C DB +43°CDB -10°CDB +43°CDB -10°CDB +43°CDB -10°CDB +43°CDB
Ambient temperature operating range Heating -20°C DB +15°CDB -20°C DB +15°CDB -20°C DB +15°CDB -20°C DB +15°CDB
Maximum number of indoor units 40 40 40 40
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. * Please refer to tube sizing charts for pipe selections and pipe length parameters
Model Number C1405DXHN8/ C1305DXHN8/ C0905DXHN8 C1405DXHN8/ C1405DXHN8/ C0905DXHN8 C1405DXHN8/ C1405DXHN8/ C1155DXHN8 C1405DXHN8/ C1405DXHN8/ C1305DXHN8
Unit 1 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8
Unit 2 14 C1305DXHN8 16 C1405DXHN8 16 C1405DXHN8 16 C1405DXHN8
Unit 3 10 C0905DXHN8 10 C0905DXHN8 12 C1155DXHN8 14 C1305DXHN8
HP 40 42 44 46
Power supply 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz 380/400/415V-3 phase/50,60Hz
Cooling capacity - (kW) 113.00 118.00 124.00 130.00
Heating capacity - (kW) 127.00 132.00 138.00 145.00
EER Cooling 3.45 3.42 3.43 3.40
COP Heating 3.91 3.86 3.83 3.83
Electric rating - cooling - Running current (AMPs) 55.0/52.0/50/0 58.0/55.0/53.0 60.0/57.0/55.0 64.0/61.0/59.0
Electric rating - cooling - Power input (kW) 32.80 34.5 36.2 38.2
Electric rating - heating - Running current (AMPs) 54.0/52.0/50.0 57.0/54.0/52.0 60.0/57/0/55.0 64.0/61.0/59.0
Electric rating - heating - Power input (kW) 32.5 34.20 36.0 37.9
Recommended fuse sizes (motor rated) 1x32 2x40 1x32 2x40 1x32 2x40 3x40
Dimensions (H/W/D) - mm 1887×2870×890 (+60) 1887×2870×890 (+60) 1887×2870×890 (+60) 1887×2870×890 (+60)
Net weight - (kg) 985 985 985 1035
Air circulation - (m3/min) 220+200+160 220+220+160 220+220+180 220+220+200
Piping connection - Gas - Inches (mm) 1 5/8 (38.1) 1 5/8 (38.1) 1 5/8 (38.1) 1 5/8 (38.1)
Piping connection - Liquid - Inches (mm) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05) 3/4 (19.05)
Piping connection - Balance - Inches (mm) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35) 1/4 (6.35)
Operating sound - normal mode - dB(A) 65.0 65.5 65.5 66.5
Operating sound - quiet mode - dB(A) 62.0 62.5 62.5 63.5
Ambient temperature operating range Cooling -10°CDB +43°CDB -10°CDB +43°CDB -10°CDB +43°CDB -10°CDB +43°CDB
Ambient temperature operating range Heating -20°C DB +15°CDB -20°C DB +15°CDB -20°C DB +15°CDB -20°C DB +15°CDB
Maximum number of indoor units 40 40 40 40
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. * Please refer to tube sizing charts for pipe selections and pipe length parameters
Model Number C1405DXHN8/ C1405DXHN8/ C1405DXHN8
Unit 1 16 C1405DXHN8
Unit 2 16 C1405DXHN8
Unit 3 16 C1405DXHN8
HP 48
Power supply 380/400/415V-3 phase/50,60Hz
Cooling capacity - (kW) 135.00
Heating capacity - (kW) 150.00
EER Cooling 3.38
COP Heating 3.79
Electric rating - cooling - Running current (AMPs) 69.0/65.4/63.0
Electric rating - cooling - Power input (kW) 39.90
Electric rating - heating - Running current (AMPs) 67.0/64.0/62.0
Electric rating - heating - Power input (kW) 39.9
Recommended fuse sizes (motor rated) 1x40 1x32
Dimensions (H/W/D) - mm 1887×2870×890 (+60)
Net weight - (kg) 1035
Air circulation - (m3/min) 220+220+220
Piping connection - Gas - Inches (mm) 1 5/8 (38.1)
Piping connection - Liquid - Inches (mm) 3/4 (19.05)
Piping connection - Balance - Inches (mm) 1/4 (6.35)
Operating sound - normal mode - dB(A) 67.0
Operating sound - quiet mode - dB(A) 64.0
Ambient temperature operating range Cooling -10°CDB +43°CDB
Ambient temperature operating range Heating -20°C DB +15°CDB
Maximum number of indoor units 40
* Condenser actual pipe connections may vary from above pipe connections shown, please refer to technical manuals for full details. * Please refer to tube sizing charts for pipe selections and pipe length parameters
Rating Conditions

The cooling and heating capacities are based on the following conditions:

Cooling: Indoor temperature 27°C DB/19°C WB, Outdoor temperature 35°C DB/24° C WB.
Heating: Indoor temperature 20°C DB, Outdoor Temperature 7°C DB 6°C WB.

All specifications are subject to change without notice.